Switch Unmanaged 16GE+2 SFP a 16 porte 10/100/1000Mbps

    Switch Unmanaged 16GE+2 SFP a 16 porte 10/100/1000Mbps

    Sizes: 44x17.8x4.4
    Box: 5
    Color: Light brown
    Certificate: CE RoHS FCC
    Comp. brand: IP-COM
    IC-G1118P-250
    Disponibile
    171,21 €
    Tasse incluse

    G1118P-16-250W

    16GE+2SFP Ethernet Unmanaged Switch With 16-Port PoE
    • Compliant with IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3z, IEEE802.3x and IEEE802.3af/at standards.
    • 16 * 100/1000 Mbps Base-T RJ45 ports for data transmission and power supply,
    • 2 * 1000 Mbps Base-X SFP slots.
    • 8K MAC address table and MAC address auto-learning.
    • IEEE 802.3x-compliant full-duplex flow control and half-duplex backpressure flow control.
    • 36Gbps backplane bandwidth.
    • Maximum power consumption of a single port: 30W; Maximum power consumption of the switch: 250W.
    • 4 modes: standard, priority, extend and VLAN.
    • Rack mounting.

     

    ModelG1118P-16-250W
    Interfaces16 * 100/1000 Mbps Base-T RJ45 ports (Data/Power)
    2* 1000 Mbps Base-X SFP port
    Lightning protection≥6KV
    Forwarding modeStore-and-forward
    Switching capability36 Gbps
    Packet forwarding rate26.8 Mpps
    Buffer2M
    MAC address table8K
    PoE supplyPorts 1-16 support standard IEEE802.3af/at 30W output per PoE port
    230W output of the total PoE Power
    Power consumption250W output the whole device
    Input voltageAC: 100-240V~50/60Hz
    Dimensions440*178.8*44mm
    Four ModesStandard: Default mode of the switch. In this mode, it works as an unmanaged switch;all ports can communicate with each other separately.
    Priority: In this mode, port 15,16,SFP1 and SFP2 serve as uplink ports, ports 1 ‒ 8 serve as high priority port. All ports can communicate with each other separately.
    Extend: In this mode, data rate of ports 9 - 14 reduces to 10 Mbps, the maximum transmission distance can be 250 meters, and all ports can communicate with each other.
    VLAN: In this mode, ports 1 - 14 of the switch can communicate with port15,16, SFP1, SFP2 separately, but cannot communicate with each other. You can enable this mode to reduce broadcast storm and isolate DHCP broadcast.
    Operating environmentOperating Temperature: 0℃~45℃ (32℉~113℉)
    Storage Temperature: -40℃~70℃ (-40℉~158℉)
    Operating Humidity: 10%~90% non-condensing
    Storage Humidity: 5%~90% non-condensing
    CertificatesFCC、CE、RoHS
    Nessuna recensione